Shenzhen Refresh Biosensor Technology Co., Ltd.

The Capsule
Electrochemical Workstation

Extreme miniaturization

Compact and Impactful

Adapting to various research needs

Significantly improving experimental convenience

Description

The Capsule Electrochemical Workstation (BioCAP) is the most highly integrated module of BioSYS, with performance indicators nearly identical. It can be configured with carbon, gold, graphene, and other electrodes.Users can modify the corresponding biochemical sensitive substances to detect specific markers, with the detection signal transmitted to mobile phones or other display terminals via Bluetooth. With an IPX8 waterproof rating, it provides a reusable version with replaceable batteries and electrodes, as well as a more compact disposable version. Users can choose solutions according to different application scenarios.

YouTube

Application
Scenarios

Research Scenarios:

Research on internal environment and metabolism, gut microbiota, cell electrochemistry, animal experiments

Other Scenarios:

Swallowable electronic capsules, implantable biosensing systems

  • BioCAP II
    Dimensions

    Φ11.5x20.5mm

    Product Type

    Single-Channel:WE, RE, CE

    Experimental Parameters

    Maximum Sampling Rate for IT/OCPT/RES
    1 kHz

    CV/LSV Scan Rate
    (0.1 - 250) mV/sec

    SWV Scan Frequency
    0.1 - 5 Hz

    Usage Frequency

    Replaceable battery and electrodes, reusable

    Usage Frequency

    Replaceable battery and electrodes, reusable

    Optional Services

    Types of electrodes, WE material

  • BioSYS-im
    Dimensions

    20×7×2 mm (tentative)

    Product Type

    Single-Channel FlexibleRE, CE, WE, WE1

    Experimental Parameters

    Maximum Sampling Rate for IT/OCPT/RES
    10 Hz

    CV/LSV Scan Rate
    (0.1 - 250) mV/sec

    SWV Scan Frequency
    0.1 - 5 Hz

    Usage Frequency

    One-time use, for implantation or ingestion scenarios

    Optional Services

    Types of Electrodes

  • Technical Specifications

    Current Measurement:±(10 pA - 500 uA), 1 pA resolution

    Potential Measurement:±(1 mV - 1200 mV)

    Bias Range:±1200mV @ 1mV

    Test Methods:IT, CV, DPV, SWV, OCPT, RES, CP, LSV

    Customizable

  • Technical Specifications

    Current Measurement: ±(100 pA - 500 uA)

    Potential Measurement:±(1 mV - 900 mV)

    Bias Range:±600 mV @ 1 mV

    Test Methods:IT, CV, DPV, SWV, OCPT, RES

    Others:Wireless Communication

    3V Button Battery Power Supply

  • Software

    Supports Android, iOS; supports cloud storage and local operation; supports sensor model import.